Screening workspace

This produces a traceable proposal for qualified human review. Protective requirements and any library candidate records are screening outputs; they do not approve a manufacturer device, certify code compliance, or replace coordination, field verification, or stamped design.

Preparing the project and draft…

Generate a complete routed proposal to download the raceway schedule. A review project keeps the generated design separate and cannot be issued. Full study histories remain in the proposal downloads. Draft not run.

Supply

Voltage is V line-to-line; capacity is kVA; available source fault current is kA; frequency is Hz; x/y/z are feet. The bundled industrial case is a synthetic example.

Advanced supply JSON

Criteria

Limits are explicit project criteria; voltage drop is percent.

Cable ampacity screening

This is tabulated ampacity screening using ambient and grouping assumptions. It is separate from detailed direct-burial IEC temperature prediction.

Advanced criteria JSON

Motor starter basis

Used for motor starter candidates. Blank values remain unknown.

Motor acceleration criterion

Optional explicit maximum acceleration time in seconds. Blank means no duration limit was supplied; it is not treated as a pass.

Optional motor fault network

Enter explicit source equivalents for an initial symmetrical RMS three-phase bolted-fault screen. Source inventory completeness is supplied metadata, not verified evidence. This study does not complete motor protection or enable Apply.

Advanced fault network JSON

Leave blank to omit. Source impedances are ohms per phase on each source bus base. Every source requires an explicit EMF, impedance, in-service state, equipment ID, and reference.

Optional fault source-profile history

Requires the exact explicit fault network above. Supply a piecewise-linear real EMF multiplier history for every modeled source from 1 at time zero to one common horizon. This is a quasi-steady balanced RMS phasor history; it is not a measured motor decay, dynamic waveform, DC peak, clearing-time, thermal-damage, or device-rating model. Multipliers change source EMF while retaining source impedance and in-service state; zero suppresses source EMF without opening the source.

Advanced fault evolution JSON

All profiles and conditions are supplied, unverified evidence. Do not infer actual motor decay from nameplate data or use these results to establish protection adequacy.

Optional cable fault thermal screen

Requires a complete fault network and supplied source-history comparison. This conditional single-event screen compares both terminal exposures through a supplied maximum total-clearing time. Choose continuous coverage to check every selected conductor against all generated bus faults and the full length of every generated cable, including faults in other cables. The time and all-source applicability claim are supplied and unverified. Its 90 °C to 250 °C copper thermoset basis assumes one event after adequate recovery. It does not calculate actual device clearing or let-through, retains a visibly limited bus-only legacy mode, does not qualify the cable, and does not complete protection. An evaluated numeric failure triggers bounded next-size conductor trials under the shared load-flow revision budget (set criteria.loadFlow.maxRevisions to 0 for evaluation only). Incomplete evidence, an infeasible candidate, or exhausted revisions blocks Apply.

Advanced cable fault-withstand JSON

Use schemaVersion 1.0.0, cableSelection mode all-modeled or selected with exact cableIds, faultSelection mode all-generated-bus-and-cable-span-faults for full continuous coverage, or all-generated-bus-fault-cases for legacy bus-only coverage, clearing with maximumTotalClearingTimeS 0.1–5, separate reference and applicabilityReference, and appliesToAllModeledSources true. thermal must state copper, maximumInitialTemperatureC no greater than 90, finalTemperatureC 250, singleEvent true, adequateRecoveryBeforeEvent true, and a reference.

Fault operating scenarios

Supply two to four named operating conditions, each with a complete explicit fault network. Reported envelopes describe the supplied cases only and do not verify true fault minima or maxima or protection adequacy.

Advanced fault scenarios JSON

Each row contains a unique id, unique reference, and study object using the fault network JSON contract. This is mutually exclusive with the single fault network input.

Equipment

Editable equipment table. kW, V line-to-line, phases, power factor, duty, and x/y/z in feet. Optional motor.rem610Thermal inputs are entered in Advanced equipment JSON; they are ABB REM610 setting-screen inputs, not a generic relay model. Optional motor.protectionTiming accepts the bounded v1 reference-current screen or v2 supplied stall-current range comparison; neither is complete motor protection, and supplied evidence remains unverified.

Use existing project equipment

Advanced equipment JSON / CSV-ready structure

Motor acceleration curves and inertia

Optional JSON object keyed by equipment ID. Enter referenced motor speed/current/power-factor/torque and load-torque curves, target speed, and motor/load inertia. The supplied values are not independently authenticated.

Advanced motor acceleration JSON

Panel location overrides

Optional requested panel locations in feet. The engine reports requested, automatic, and effective positions; removing a row restores automatic placement.

Permitted corridors

Node coordinates are feet; edge width/depth are inches.

Review existing project trays

Corridor graph JSON

Proposal

No proposal generated. Load a sample or enter JSON, then generate.